Analysis of Common Faults in High and Low Voltage Switchgear
Guangxi Electric Power will analyze the common faults of high and low voltage switchgear, which can be mainly divided into insulation, conductivity, and mechanical faults.
1. Refusal to operate and erroneous operation faults
This is the main fault of high voltage switchgear, and its causes can be divided into two categories. The main reason is due to mechanical faults in the operating mechanism and transmission system, specifically manifested as mechanism jamming, component deformation, displacement or damage, loose or jammed circuit breaker cores, loose or broken pins, and failure of tripping. The second category involves electrical control and auxiliary circuits, mainly manifested as poor contact in secondary wiring, loose connections, incorrect connections, burning of circuit breaker coils due to mechanism jamming or faulty switches, failure of auxiliary switches, and faults in the operating power supply, contactors, micro switches, etc.
Breaking and closing faults.
Circuit breaker faults are mainly caused by the circuit breaker body, while oil-less circuit breakers mainly exhibit oil spray short circuits, burning of the arc extinguishing chamber, insufficient breaking capacity, and explosions during closing. For vacuum circuit breakers, the main issues are gas leakage in the arc extinguishing chamber, reduced vacuum, re-ignition of capacitor banks, and ceramic tube rupture.
2. Insulation failure.
The insulation layer should properly handle the relationship between various voltages (including operating voltage and various overvoltages), various pressure limiting measures, and insulation strength. Strive to make the product both safe and economical. The main manifestations of insulation faults are: external insulation flashover breakdown to ground, internal insulation flashover breakdown to ground, inter-phase insulation flashover breakdown to ground, lightning overvoltage flashover breakdown to ground, flashover of porcelain bottle insulators and capacitor insulators, pollution flashover, breakdown, explosion, CT flashover, breakdown, explosion, and porcelain bottle rupture.
3. Current carrying failure.
Current carrying faults occurring at voltage levels of 72~12KV are mainly caused by poor contact of switch plugs leading to contact head burning.
External forces and other faults.
Such as unpredictable external forces and unexpected faults like external collisions, natural disasters, and short circuits caused by small animals.